VISITAS RECIENTES

AUTISMO TEA PDF

AUTISMO TEA PDF
TRASTORNO ESPECTRO AUTISMO y URGENCIAS PDF

We Support The Free Share of the Medical Information

Enlaces PDF por Temas

Nota Importante

Aunque pueda contener afirmaciones, datos o apuntes procedentes de instituciones o profesionales sanitarios, la información contenida en el blog EMS Solutions International está editada y elaborada por profesionales de la salud. Recomendamos al lector que cualquier duda relacionada con la salud sea consultada con un profesional del ámbito sanitario. by Dr. Ramon REYES, MD

Niveles de Alerta Antiterrorista en España. Nivel Actual 4 de 5.

Niveles de Alerta Antiterrorista en España. Nivel Actual 4 de 5.
Fuente Ministerio de Interior de España

jueves, 7 de noviembre de 2024

TOURNIQUET SICH. STRENGTHENED INDIVIDUAL COMBAT HYBRID TOURNIQUET . TQ

Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD

SICH Tourniquet by Dr. Joshua Bobko, MD
TOURNIQUET SICH. STRENGTHENED INDIVIDUAL COMBAT HYBRID TOURNIQUET . TQ

Dr. Joshua Bobko, MD from #First Care Provider First Care Provider @1stCarePRovider


TOURNIQUET SICH.  STRENGTHENED INDIVIDUAL COMBAT HYBRID TOURNIQUET . TQ 







El torniquete es empleado en Medicina Táctica, su origen parte de la necesidad de controlar la hemorragia durante amputaciones quirúrgicas realizadas en el campo de batalla, y su uso ya es conocido desde la antigua Roma. A Ambroise Pare (aprox.1510-1590) se le atribuye no solo la creación del término “torniquete”, también ser el primero en recomendarlo para su uso quirúrgico y realizar la primera modificación conocida (colocó un tornillo sobre el vaso principal de una extremidad y lo apretó mediante el incremento de la tensión sobre una correa circunferencial). 

A lo largo de la historia, el torniquete ha tenido otras modificaciones, en el siglo XVII William Fabry y Etienne Morel utilizaron un torno con giro sobre un palo, con el objetivo de apretar aún más una banda de constricción. En el siglo XIX Lister y Esmarch usaron torniquetes para introducir la cirugía “sin sangre” y Gushing en 1904 introduce un torniquete neumático.

A mediados del siglo XX, el torniquete se emplea durante cirugías en extremidades para obtener “campos quirúrgicos sin sangre”. En el campo militar, tras estudios realizados a víctimas de combate en Vietnam, se estimó que su aplicación apropiada y a tiempo habría podido salvar 105 vidas de un conjunto de 277 soldados fallecidos. Según un informe relativo a la guerra en Irak, la aplicación correcta de un torniquete, hubiera evitado más del 50% de los fallecimientos debidos a hemorragias arteriales en extremidades.

En la actualidad, personal de la armada, infantería de marina, y médicos tácticos, incluyen torniquetes en sus equipos de primeros auxilios, formando a los combatientes para que puedan usarlos adecuadamente.

¡Torniquete, uno de los asombrosos SalvaVidas! 👍

@boerelite @ptmcolombia 







Bibliografía: Gerard S Doyle, Peter P Taillac. PREHOSPITAL EMERGENCY CARE (ed. esp.), VOL 1, NÚM. 4, 2008.



TQ   TOURNIQUET SICH STRENGTHENED INDIVIDUAL COMBAT HYBRID TOURNIQUET

TQ SICH by @DrRamonREYESMD












 SICH-Ukraine Company is leading Ukrainian producer of SICH-Tourniquet, instrument No. 1 in modern civil and military first-aid boxes.
It is official supplier of the Ministry of Defense of Ukraine, the National Guard and Police.
The company was established in 2014 by a team of entrepreneurs and volunteers headed by Aleksandr Hadomskyi

The first and the main task put forward to the designers and developers at the moment of company formation under the hybrid war conditions was to create our own, special construction of tourniquet able to control massive bleeding in any state, under any weather conditions, being wet, snow-covered, dirty, heated or cold, in any extreme loads. Having passed all stages of development, testing and consultations the team managed to find effective and complex solution that was realized in original and patented construction named “SICH-tourniquet”.

“SICH” is a symbol of Ukrainian strength.
That’s why our company has this strong and victory hardened name!
On the whole, SICH-tourniquet history is a history of uniting a big number of people, a team of designers, military men, volunteers, and all this was made for one noble mission – to save person’s life.

Soon the products of our company got interest from abroad. It was decided to expand the company out of Ukraine. As a result of successful negotiations with Rimas Žilinskas and with his support in December 2017 SICH Europe subsidiary company was founded in Lithuania.
Parameter:
Length: 93 cm
Thickness: 4 cm
The thickness of the inner loop is 2.5 cm

METAL FITMENTS
Light but rather resistant duraluminum fitment can stand extreme working loads.
NO ENJURIES
Soft coating + integral buckle and platform + incorporated patented telescopic mechanism prevent from soft tissues pinching and from their atrophy, if the tourniquet is applied.
TRIANGLE FOR FIXING
Our special patented form of triangle enables quickly and securely to fix the stick and the tail of the rope.
ERGONOMICS
No any extra millimeter. The optimal size of the platform and its holder selected an result of numerous tests conducted under extreme conditions. Maximum square area and force of holder blocking compared with other tourniquets.
ROPE FOR MARKING
Due to special grey coating it is possible to make markings with any sharp object (bullet cartridge, nail, etc.)
EXTRASTRONG STICKING TECHNOLOGY
Special patented technology ensures extra strong sticking of the tape and its secure and effective operation at any state, being wet, snow-covered, dirty, in frost and heat.










 Hemos recibido desde el fabricante los TQ SICH fabricados en Lituania Union Europea 
en pocos dias conclusiones 


producto
  • Triángulo para la fijación: nuestra forma especial patentada de triángulo permite fijar de forma rápida y segura el palo y la cola de la cuerda.
  • Cuerda para marcar: debido al revestimiento gris especial, es posible hacer marcas con cualquier objeto afilado (cartucho de bala, clavo, etc.).
  • Sin lesiones: el recubrimiento suave + la hebilla integral y la plataforma + el mecanismo telescópico patentado incorporado evitan el pellizco de los tejidos blandos y su atrofia, si se aplica el torniquete.
  • Accesorios de metal: el accesorio de duraluminio ligero pero bastante resistente puede soportar cargas de trabajo extremas.
  • Tecnología de adherencia extrarresistente: la tecnología patentada especial garantiza una adherencia extrafuerte de la cinta y su funcionamiento seguro y efectivo en cualquier estado, mojado, cubierto de nieve, sucio, con escarcha y calor.




TACTICAL MEDICINE TACMED España by EMS Solutions International 

http://emssolutionsint.blogspot.com.es/2017/09/tactical-medicine-tacmed-espana-by-ems.html


MAS LIBROS MEDICINA Y SALUD 


Dr. Ramon Reyes, MD

Les Esperamos en nuestro Grupo en TELEGRAM Soc. IberoAmericana de Emergencias




SICH VIDEOS

  Torniquete SICH ha sido utilizado con exito en Republica Dominicana en la UNIDAD ELITE TOP Unidad Contra Terrorismo del Ministerio de DEFENSA by @DrRamonREYESMD
 Torniquete SICH ha sido utilizado con exito en Republica Dominicana en la UNIDAD ELITE TOP Unidad Contra Terrorismo del Ministerio de DEFENSA by @DrRamonREYESMD

 Torniquete SICH ha sido utilizado con exito en Republica Dominicana en la UNIDAD ELITE TOP Unidad Contra Terrorismo del Ministerio de DEFENSA by @DrRamonREYESMD

 Torniquete SICH ha sido utilizado con exito en Republica Dominicana en la UNIDAD ELITE TOP Unidad Contra Terrorismo del Ministerio de DEFENSA by @DrRamonREYESMD
History of tourniquets evolution
Etienne Morel, Jean-Louis Petit, Johannes Friedrich and Bernhard Rudolf Konrad von Langenbeck…
The names of these gentlemen are not widely known. But millions of people who have survived thanks to the tourniquets should be very grateful, first of all, to these four people.

Starting from the 17th century and till the Second World War each of them greatly contributed to development of any instruments for bleeding control.
The first samples of modern tourniquets with crowfoot mechanism (something like improved boxes by Etienne Morel) appeared in the late nineties. Americans were the first in this process. The prototypes were extensively improved and modified, and they started to be more and more popular among military and medical men, and soon among civil people as well.
For the last three decades while performing some missions in the countries of Middle East the NATO military forces have gained both fighting experience and very important medical experience in urgent prehospital help.

On analyzing statistical information, health professionals found out that about 75 per cent of battlefield casualties was caused by extensive bleeding, and the most of the injured with any damages of great vessels had very high chances to survive in case of timely bleeding control.
Later these statistical data and economical statistical information were combined.

The NATO country-members spent from one million to some dozens of USD millions on training one highly qualified military specialist, and it took approximately from 5 to 20 years (subject to the military branch). Soldier’s death caused by failure to stop bleeding undermined the chances to perform the tasks almost to zero, moreover, it tactically made any military unit weaker, and achievement of strategic goals was under the threat of failure, it brought to naught all the enormous financial resources spent by any country on military specialist training.
Ideological factor was one of the constituent too. The democratic countries – members of the NATO which declared person’s life as the highest value, could not bear with such defect in the military medical pack. The military officer’s image was on the line.
It was high time for urgent need in tourniquets and hemostatic agents which are reliable and fast in use at the same time, but also it needed correction and improvement of available battle site rescue protocols.
And at last in 2004 as a result of wholescale battle site and laboratory experiments carried out by the military institute of surgery of the USA (USAISR), the old rubber Esmarch’s tourniquets were substituted by new tourniquets recommended for using by military and rescue officers:

SWAT-Tourniquet (Stretch Wrap And Tuck / Розтягни Підверни Та Оберни)
SWAT-Tourniquet (Stretch Wrap аnd Tuck).

This device is just a piece of elastic rubber of 130 cm wide and 10,5 cm long with imprinted rhombic symbols and ovals along the whole length. One should stretch the tourniquet to the moment when rhombic symbols turn to squares. It means the proper application of the tourniquet. The tourniquet is fixed by tucking the edge under the loop.

CAT-Tourniquet (Combat Application Tourniquet) .
This is the improved sample of classical tourniquet with plastic windlass.
Turning of the stick increases the pressure on the limb and on great vessels. It consists of synthetic adhesive tape, internal sling, buckle, fixing bracket of the windlass, and the windlass itself. It is possible for any experienced user to stop bleeding within 30 seconds with just one hand.

CAT-Tourniquet (Combat Application Tourniquet / Джгут Бойового Застосування)
SOF-Tourniquet (Special Operation Forces Tourniquet / Джгут Сил Спеціальних Операцій)
SOF-Tourniquet (Special Operation Forces Tourniquet).

It is an enhanced sample of classical tourniquet with metal lever rod. It consists of wide synthetic tape, V-type buckle with a wide hook and a sliding bar, triangular fixing unit for level rod and the lever rod itself. The peculiar features of this construction enable to fix the tourniquet quickly on the limp and to block bleeding with just one hand.

MA-Tourniquet (Mechanical Activated Tourniquet).
This tourniquet was designed upon the request of the Ministry of Defense of the USA, and later the first responding services accepted this device for usage. It is made as C-shaped hook. The tourniquet consists of synthetic tape, buckle, turning mechanism and lever rod in the form of semicircle. It is applied around a limb by one hand. Thanks to special turning mechanism it is possible to regulate the pressuring force and to unfasten the tourniquet quickly, if necessary.

MA-Tourniquet (Mechanical Activated Tourniquet / Механічно Активований Джгут)
RATS (Rapid Application Tourniquet System / Джгут із Системою Швидкого Накладання)
RATS (Rapid Application Tourniquet System)

The tourniquet is designed as a flat lacing from a resistant vulcanized rubber with nylon cover which is 121 cm long, 0,6 cm wide, and it is fixed on the aluminum block with one end. The tourniquet is fixed by its wrapping around a limb and drawing a loose end into the hole of aluminum fixing block by forming a self-tightening loop. The pressure increases with each new turn of the tourniquet around a limp (Esmarch type).

In 2011 a special investigation was carried out for analyzing 79 tourniquets applied on 64 limps of 54 injured people:
— the tourniquet was applied by paramedics of special purpose forces in 47 cases (59%),
-by paramedics from aviation department in 17 cases (22%),
— by military doctors in 12 cases (15%),
— by surgeons in 3 cases (4%).
It should be noted that in 71 cases (90%) of 79 it was the tourniquets of САТ type.



Upon delivery of the injured to hospital it was found out that 54 of 65 limps had pulsation, but pulsation was not observed in 11 limbs. In 83 per cent of cases the tourniquets were applied for stopping venous bleeding, and only 17 per cent was used for arterial bleeding control. However, only in 5 cases from 14 cases the tourniquets were applied for arterial bleeding control in proper way. The statistical data were published in JSOM magazine in 2013.
In the same 2013 the Military Medicine published the results of field tourniquets testing for period from February to May 2010 conducted by the 1st battalion of the 6th naval infantry regiment of the USA. The military officers found out that keeping the tourniquets out of the individual medical pack, namely, on the breast or unloading, decreases their efficiency for 43 per cent. Negative effect of high and low temperature, and ultraviolet light on synthetic material was proved with some features.
European countries also did not stay aside from historical processes. Crimean annexion and the war on the east of Ukraine greatly influenced on the development of military and field medicine. It should be noted that military medicine of Ukraine made its way from complete decay to a sudden recovery just for some years. And if during the first year of the war the foreign detachments assisted Ukraine in delivering the first aid and trained the medical staff, and the national medical packs of soldiers were completed according to the standards of 50-ies years, in some years the country started production of national modern devices for bleeding control, and it shares its unique experience in using them on battle site with the whole world.
Constant military actions in the state of limited financial resources, death of thousands of military and civil people forced Ukrainian doctors, chemists and volunteers start national development and production of efficient and available medical and chemical hemostatic agents.
So, as a result of laboratory testing and hundreds experiments on the field, the first Ukrainian chemical kaolinic hemostatic agent was designed and put into production in 2015. According to its efficiency criteria it left behind the famous American Quick Clot. Moreover, SICH-Tourniquet, the tourniquet for bleeding control with crowfoot mechanism, was introduced to the world, it is the improved and strengthened enhanced hybrid of two worldly famous versions of tourniquets, САТ and SOF-T.


SICH-Tourniquet (Strengthened Individual Combat Hybryd Tourniquet) is a strengthened hybrid of two famous tourniquets. It is achieved through using metal strengthening components. Due to aluminum furniture and special patented adhesive tape, integral structure and telescopic platform, this unique tourniquet stood under double pressure and worked successfully even being dirty from bleeding, from any grease or oil, and it didn’t lose its efficiency at extremely low or high temperature (-40 / +50). The tourniquet did not impact soft tissues at its application. Moreover, it can be applied with just one hand.
In summer 2015 the independent consumers and experts (doctors, volunteers and military people) have conducted extensive testing of tourniquets made by famous Ukrainian producers of those times. Based on the results of testing, SICH-Tourniquet occupied the first place and later it became the official tool for individual packs in the Military Forces of Ukraine, which were packed according to NATO standards, and for packs of Ukrainian National Guard and Police.

The history of tourniquets testing is enriched with new events.

At the end of 2017 the volunteers of Wilni UA Ukrainian Charity Fund initiated and organized detailed examination of Ukrainian and American tourniquets. Based at Ukrmetrteststandard State Company (the company is worldly certified), the qualified employees and instructors of TSSS conducted extensive examination of reliability, performance and stability of modern tourniquet samples. Without any exaggeration it should be stated that there were not any similar tests in Ukraine and, in particular, in the world.

In the course of testing the specialists studied tourniquets capability to keep relatively constant pressure effecting on any limb (350-300 Mmhg) for two hours under the following conditions and in such modes:

at room temperature (24с +/- 7с), if the tourniquet is dry;
at room temperature (24с +/- 7с), if the tourniquet is wet;
at room temperature (24с +/- 7с), if the tourniquet is soaked in diesel;
if the sample is frozen before to -40C;
if the sample is heated to + 50C.
Considering the results of testing, SICH and CAT7 had the best features, but SICH showed better results at low and high temperature.

The examination protocols and tests video can be watched, if to click on the relevant link.

One of the most famous medical protocols of pre-hospital aid in combat conditions was developed by the Department of Military Medicine of the USA in 1996 (TC3 — Tactical Combat Casuality Care). According to this protocol one should make the following:

1 – stop critical bleeding.
A — Airway.
В — Breathing.
С — Circulation.
D — Disability.
Е – Exposure (additional examination, heating).

The protocol prescribes:

the same location of tourniquet for all soldiers of the unit;
to handle fa medical emergency to the partner using exclusively his individual medicine box (bleeding is controlled with the injured soldier’s tourniquet)
the skills of applying tourniquet should be trained almost to reflexive level, both directly on yourself and on a partner;
availability of mechanical tourniquet in solder’s medical box (CAT, SICH, SOF-T) or rubber band tourniquets (SWAT, RATS), hemostatic agents (Quick Clot, Cellox gause) or roller bandages, bandage or elastic roller bandage, nasopharyngeal tube, occlusal onlay, decompression needle or catheter, warm-air heat exchange device, trauma shears, fabric-backed plaster, markers, nitril gloves.
Tourniquet is the first and the most effective device for bleeding control.
Tourniquet application and vascular occlusion is one of the most important operations among all the actions of the first aid for great vessels bleeding control.

The tourniquet and necessary skills save life of military person on any battle field, or any Mechanical tourniquets of new generation (SICH, CAT, SOF-T) are applied successfully within 10-30 seconds individually with just one hand.

The methodology of tourniquet application is different subject to its structure. But the general rules are constant and stay without any changes:

the tourniquet is applied above the wound in the distance of not less 5 cm (it is equal to the width of adult’s three fingers kept together);
the square under the tourniquet should be previously cleaned from any solid objects (pockets should be empty, any chains should be removed, any bandages etc.);
before applying the tourniquet some soft material should be placed between the body and the tourniquet (if it is not available) for minimization of any soft tissues impaction and necrosis;
the tourniquet is fastened till complete stop of bleeding;
the time of tourniquet application should be indicated the note or directly on the tourniquet (if it is provided according to the construction);
nobody except for the medical staff is allowed to unfasten or to remove the tourniquet.
it is prohibited to place any bandages on the applied tourniquet.
Tourniquet application is not the same as limb loss. Although there is such a risk, if the applied tourniquet is not removed for a long time and blood circulation in the limp is not restored. The period of time allowed for stopping blood circulation in the limb depends on many factors (physiology, temperature of environment, applied force and compression square).

The imaginary “red” indicator of time which should not be exceeded is 2 hours. In most cases the limb is lost not because of the applied tourniquet, but, mainly, projectile traumas followed by major bleeding caused by extensive injuries of soft tissues, great vessels, cartilages and bones. High kinetic energy of bullet slug or a piece of mortar bomb produces missile wounds, and there are secondary wounds of great vessels and limbs breaks.

In case of gunshot wounds it is very important to consider the nature of wounds, if it is а through-and-through or blunt wound. It is conditional upon the fact the outcome bullet hole can be located far from its income hole, so improper diagnostics can be the reason for critical bleeding and death of wounded person at transportation.

Military conflicts in different corners of the world do not disappear and make the power players to search for diplomatic and military solutions. Efficient tools in soldiers’ medical boxes along with weapon and diplomacy strengthen the position of some states at the international political arena. That’s why, the developed countries pay their attention to improvement of available devices for medical pre-hospital emergency. And who knows, maybe, a new revolutionary instrument for saving people’s life is born now in the laboratories of leading institutes.



 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD
 Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD

Torniquete SICH en Pediatricos by Dr. Ramon REYES, MD

 Promoting STB from FirstCare Provider worldwide thanks for your help to reduce dead all around the world by Dr. Ramon Reyes, MD
Dr. Joshua Bobko, MD from #First Care Provider First Care Provider @1stCarePRovider





Posted in the Facebook Group




Thanks a lot Dr. Joshua Bobko,MD, for this professional and personal oppinion, for us, people that do not have access some times to originals TQ made in USA,,, for mw is really important somebody with your moral and professional reputation talk about this and some other items to help reduce mortality worldwide. Thanks again I hope to see you in the next CTECC meeting. Best regards hugs from remote sea in Turkey... by Dr. Ramon Reyes, MD @DrRamonReyesMD #DrRamonReyesMD






Hazte Instructor del Programa Stop The Bleed the FIRST CARE PROVIDER avalado pro Departemt of Homeland Security de los Estados Unidos 
https://emssolutionsint.blogspot.com/2017/07/stop-bleed-bleeding-control-basic.html
Aqui tienes todas las forma para hacerte Instructor del Programa STOP THE BLEED del Colegio Americano de Cirujanos 

Paquete en Español STOP THE BLEED    



Registrarse como instructor Stop The Bleed 

#leer #conocimiento es #poder es #libertad
#COMPARTIR: Casi 1000 #MANUALES  #LIBROS #MEDICINA #ENFERMERIA, etc. EN #PDF #RATIS, sin trucos para #descargar

by EMS SOLUTIONS INTERNATIONAL

Dirigido por
by @DrRamonReyesMD  #DrRamonReyesMD

Hemos estado entrenando al personal de escolta del Ministro de Defensa de Republica Dominicana y en las practicas del uso del torniquetes hemos utilizado el CAT, SAM XT, SICH, TIE, DINPRO, los Mejores valorados por instructores y más de 48 Estudiantes;

1. DINPRO ganador Ucrania https://emssolutionsint.blogspot.com/2022/12/torniquete-dinpro-hecho-en-ucrania.html

2. SICH Ucrania https://emssolutionsint.blogspot.com/2023/05/torniquete-strengthened-individual.html

3. TIE España https://emssolutionsint.blogspot.com/2017/01/torniquete-compresor-de-emergencias.html

Mayo 23-25 del 2023 

Ministerio de Defensa de la Republica Dominicana 


Advertencia: El Dr. Ramon Reyes, MD no tiene compromisos personales, ni comerciales con ninguna de las marcas anteriormente mencionada

Contactos con el Dr. Ramon Reyes, MD https://emssolutionsint.blogspot.com/2016/12/dr-ramon-reyes-diaz-md-emt-t-dmo.html





Pinterest

Twitter

Blog

Gracias a todos el Canal somos mas de  1000 participantes en WhatsApp. Recordar este es un canal y sirve de enlace para entrar a los tres grupos; TACMED, TRAUMA y Científico. ahí es que se puede interactuar y publicar. Si le molestan las notificaciones, solo tiene que silenciarlas y así se beneficia de la informacion y la puede revisar cuando usted así lo disponga sin el molestoso sonido de dichas actualizaciones, Gracias a todos Dr. Ramon Reyes, MD Enlace al 




Enlace a Científico https://chat.whatsapp.com/IK9fNJbihS7AT6O4YMc3Vw en WhatsApp 

TELEGRAM Emergencias https://t.me/+sF_-DycbQfI0YzJk  

TELEGRAM TACMED https://t.me/CIAMTO



3 comentarios:

  1. como puedo registrarme como instructor stop de bleed, lo intente en el link que esta al final y me marco error, por su atencion gracias

    ResponderEliminar
  2. Saludos doctor, el enlace para STOP THE BLEED no funciona, gracias por sus aportes

    ResponderEliminar
  3. saludos etimado doctor los enlace para descargar el paquete de STOP THE BLEED y para registrase como instructor no funcionan..gracias

    ResponderEliminar