Rapid Intraosseous Access EZ-IO / Dispositivo para Acceso Rápido Intraoseo EZ-IO. Retrospective analysis of 1000 uses of intraosseous access.

Rapid Intraosseous Access EZ-IO / Dispositivo para Acceso Rápido Intraoseo EZ-IO


Rapid Intraosseous Access EZ-IO / Dispositivo para Acceso Rápido Intraoseo EZ-IO
 2014 Jun 30. pii: emermed-2014-203588. doi: 10.1136/emermed-2014-203588. [Epub ahead of print]

Saving the critically injured trauma patient: a retrospective analysis of 1000 uses of intraosseous access.

Abstract

OBJECTIVE:

Intraosseous access (IO) is becoming increasingly accepted in adult populations as an alternative to peripheral vascular access; however, there is still insufficient evidence in large patient groups supporting its use.

METHODS:

Retrospective review. This paper reports on the use of IO devices over a 7-year period from August 2006 to August 2013 during combat operations in Afghanistan. A database search of the Joint Theatre Trauma Registry (JTTR) was carried out looking for all the incidences of IO access use during this time. Excel (Microsoft) was used to manage the dataset and perform descriptive statistics on the patient demographics, injuries, treatments and complications that were retrieved.

RESULTS:

1014 IO devices were used in 830 adult patients with no major complications. The rate of minor complications, the majority of which were device failure, was 1.38%. 5124 separate infusions of blood products or fluids occurred via IO access, with 36% being of packed red cells. On average, each casualty received 6.95 different infusions of blood products and fluids, and 3.28 separate infusions of drugs through IO access. 32 different drugs were infused to 367 patients via IO, the most frequent being anaesthetic agents. IO access was used in the prehospital environment, during tactical helicopter evacuation and within hospitals.

CONCLUSIONS:

IO access can be used to administer a wide variety of life-saving medications quickly, easily and with low-complication rates. This highlights its valuable role as an alternative method of obtaining vascular access, vital when resuscitating the critically injured trauma patient.
Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://group.bmj.com/group/rights-licensing/permissions.

KEYWORDS:

Equipment Evaluation; Military; Prehospital Care; Resuscitation; Trauma, Majot Trauma Management

PMID:
 
24981009
 
[PubMed - as supplied by publisher]
Rapid Intraosseous Access EZ-IO / Dispositivo para Acceso Rápido Intraoseo EZ-IO
Rapid Intraosseous Access EZ-IO / Dispositivo para Acceso Rápido Intraoseo EZ-IO


Enlace para ampliar información acerca de esta maravilla de la medicina de emergencias

 http://www.vidacare.com/admin/files/T427RevC-Insert-RemPoster.pdf


Tema Relacionado Catéteres Intraoseos  y Nueva RCP 2010



Dr. Ramon Reyes, MD     EZ-IO Clinical Principles Course

Related: http://emssolutionsint.blogspot.com/2015/04/spanish-army-chooses-pyng-medical-fast1.html




Cortesía
EMS España / Emergency Medical Services en España
@EMSESP
Follow me / INVITA A TUS AMIGOS A SEGUIRNOS
https://www.facebook.com/drramonreyesdiaz
@drramonreyesdiaz
Dr. Ramon Reyes Diaz, MD